Protective and safety equipment as well as components that facilitate servicing (e.g. non-return valves, safety valves, overflow valves, shut-off valves) must be installed in accordance with national regulations and standards.
[Docking-ComponentNotesParagraph]
The heat pump prioritises hot water charging. When the firewood boiler (EM1) is in use, the heat pump and any immersion heater are disconnected when the temperature rises on the temperature sensor (EM1-BT52) and they restart when the temperature drops.
Self-circulation through the heat pump is prevented by the non-return valve (RM1). The boiler sensor (EM1-BT52) is placed in the intended submerged tube on the accumulator tank (EM1-CP1).
Ensure that the system has the required pressure.
See the relevant Installer Manuals for more information.
The heat pump prioritises hot water charging. When the firewood boiler (EM1) is in use, the heat pump and any immersion heater are disconnected when the temperature rises on the temperature sensor (EM1-BT52) and they restart when the temperature drops.
Self-circulation through the heat pump is prevented by the non-return valve (RM1). The boiler sensor (EM1-BT52) is placed in the intended submerged tube on the accumulator tank (EM1-CP1).
Ensure that the system has the required pressure.
See the relevant Installer Manuals for more information.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB100 |
Heat pump system |
NIBE S1256 |
|
|
-EB100-BT25 |
External supply temperature sensor |
Included in AXC 40 |
|
|
-EB100-GP10 |
External heating medium pump |
||
|
-BT1 |
Outside sensor |
Included in S1256 |
|
|
-QM12 |
Filling valve, brine |
||
|
-QM31 |
Shut-off valve, heating medium supply line |
||
|
-QM42 |
Vent valve, brine in |
||
|
-QZ2 |
Filterball, heating medium |
Included in S1256 |
|
|
-QZ3 |
Filterball, brine |
Included in S1256 |
|
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
3 |
Cold water connection |
||
|
4 |
Hot water connection |
||
|
6 |
Brine connection, supply |
||
|
7 |
Brine connection, return |
||
|
9 |
Connecting hot water heater |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 40 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 40 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-QZ20 |
Filling kit |
KB 25/ KB 32 |
KB 25 (max 12 kW), KB 32 (max 30 kW) |
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-CM2 |
Level vessel, brine |
Included in S1256 |
Level vessel in open system |
|
-FL2 |
Safety valve, heating medium |
||
|
-FL3 |
Safety valve, brine |
Included in S1256 |
|
|
-RM1 |
Non-return valve |
||
|
-QM34 |
Shut off valve, brine out |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB100 |
Heat pump system |
NIBE S1155/S1156 |
|
|
-EB100-BT6 |
Controlling hot water sensor |
Included in S1155/S1156 |
|
|
-EB100-BT7 |
Display hot water sensor |
Included in S1155/S1156 |
|
|
-EB100-BT25 |
External supply temperature sensor |
Included in S1155/S1156 |
|
|
-EB100-GP10 |
External heating medium pump |
||
|
-BT1 |
Outside sensor |
Included in S1155/S1156 |
|
|
-QM12 |
Filling valve, brine |
||
|
-QM31 |
Shut-off valve, heating medium supply line |
||
|
-QM42 |
Vent valve, brine in |
||
|
-QZ2 |
Filterball, heating medium |
Included in S1155/S1156 |
|
|
-QZ3 |
Filterball, brine |
Included in S1155/S1156 |
|
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
6 |
Brine connection, supply |
||
|
7 |
Brine connection, return |
||
|
9 |
Connecting hot water heater |
||
|
-CP1.1 |
Storage tank |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 40 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 40 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-QZ20 |
Filling kit |
KB 25/ KB 32 |
KB 25 (max 12 kW), KB 32 (max 30 kW) |
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-CM2 |
Level vessel, brine |
Included in S1155/S1156 |
Level vessel in open system |
|
-FL2 |
Safety valve, heating medium |
||
|
-FL3 |
Safety valve, brine |
Included in S1155/S1156 |
|
|
-RM1 |
Non-return valve |
||
|
-QM34 |
Shut off valve, brine out |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB100 |
Heat pump system |
NIBE F1245 |
|
|
-EB100-BT25 |
External supply temperature sensor |
Included in AXC 40 |
|
|
-EB100-GP10 |
External heating medium pump |
||
|
-BT1 |
Outside sensor |
Included in F1245 |
|
|
-HQ1 |
Particle filter, heating medium |
F1245 includes a particle filter, which should be supplemented with a shut-off valve. |
|
|
-QM12 |
Filling valve, brine |
||
|
-QM31 |
Shut-off valve, heating medium supply line |
||
|
-QM42 |
Vent valve, brine in |
||
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
3 |
Cold water connection |
||
|
4 |
Hot water connection |
||
|
6 |
Brine connection, supply |
||
|
7 |
Brine connection, return |
||
|
9 |
Connecting hot water heater |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 40 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 40 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-QZ20 |
Filling kit |
KB 25/ KB 32 |
KB 25 (max 12 kW), KB 32 (max 30 kW) |
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-CM2 |
Level vessel, brine |
Included in F1245 |
Level vessel in open system |
|
-FL2 |
Safety valve, heating medium |
||
|
-FL3 |
Safety valve, brine |
Included in F1245 |
|
|
-RM1 |
Non-return valve |
||
|
-QM34 |
Shut off valve, brine out |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB100 |
Heat pump system |
F1355 |
|
|
-EP14 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
|
|
-EP15 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
|
|
-EB100-BT6 |
Controlling hot water sensor |
Included in F1355 |
|
|
-EB100-BT7 |
Display hot water sensor |
Included in F1355 |
|
|
-EB100-BT25 |
External supply temperature sensor |
Included in F1355 |
|
|
-EB100-BT71 |
External return line sensor |
Included in F1355 |
|
|
-EB100-GP10 |
External heating medium pump |
||
|
-EB100-QN10 |
Diverter valve, heating/hot water |
See the valve’s manual for a port description. |
|
|
-BT1 |
Outside sensor |
Included in F1355 |
|
|
-FL10 |
Safety valve, brine |
||
|
-FL11 |
Safety valve, brine |
||
|
-FL12 |
Safety valve, heating medium |
||
|
-FL13 |
Safety valve, heating medium |
||
|
-QM33 |
Shut-off valve, brine in |
||
|
-QM50 |
Shut off valve, brine |
||
|
-QM52 |
Shut off valve, brine |
||
|
-QM55 |
Shut-off valve, heating medium |
||
|
-QM57 |
Shut-off valve, heating medium |
||
|
-QZ2.1 |
Filterball, heating medium |
Included in F1355 |
|
|
-QZ2.2 |
Filterball, heating medium |
Included in F1355 |
|
|
-QZ2.3 |
Filterball, heating medium |
Included in F1355 |
|
|
-QZ2.4 |
Filterball, heating medium |
Included in F1355 |
|
|
-RM10 |
Non-return valve |
Included in F1355 |
|
|
-RM11 |
Non-return valve |
Included in F1355 |
|
|
-RM12 |
Non-return valve |
Included in F1355 |
|
|
-RM13 |
Non-return valve |
Included in F1355 |
|
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
6 |
Brine connection, supply |
||
|
7 |
Brine connection, return |
||
|
-CP1.1 |
Storage tank |
||
|
-CP4 |
Additional water heater |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 50 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 50 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-EB1 |
Step-controlled additional heat/electric boiler |
||
|
-RN1 |
Trim valve |
||
|
-QZ1 |
Hot water circulation (HWC) |
||
|
-QZ1-AA25 |
AXC module |
Included in AXC 50 |
|
|
-QZ1-BT70 |
Supply temperature sensor, HWC |
Included in AXC 50 |
|
|
-QZ1-FQ3 |
Mixer valve, HWC |
||
|
-QZ1-GP11 |
Circulation pump, HWC |
||
|
-QZ1-RM1 |
Non-return valve, HWC |
||
|
-QZ1-RN1 |
Trim valve, HWC |
||
|
-RM1 |
Filling connection |
||
|
-QM33 |
Shut off valve, brine flow |
||
|
-XL27 |
Filling brine |
||
|
-XL28 |
Filling brine |
||
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-BP6 |
Pressure gauge, brine |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-CM3 |
Expansion vessel, brine |
||
|
-FL2 |
Safety valve, heating medium |
||
|
-FL3 |
Safety valve, brine |
Included in F1355 |
|
|
-RM1 |
Non-return valve |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB100 |
Heat pump system |
F1345-24/30 |
|
|
-EP14 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
|
|
-EP15 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
|
|
-EB100-BT6 |
Controlling hot water sensor |
Included in F1345-24/30 |
|
|
-EB100-BT7 |
Display hot water sensor |
Included in F1345-24/30 |
|
|
-EB100-BT25 |
External supply temperature sensor |
Included in F1345-24/30 |
|
|
-EB100-BT71 |
External return line sensor |
Included in F1345-24/30 |
|
|
-EB100-GP10 |
External heating medium pump |
||
|
-EB100-QN10 |
Diverter valve, heating/hot water |
See the valve’s manual for a port description. |
|
|
-BT1 |
Outside sensor |
Included in F1345-24/30 |
|
|
-FL10 |
Safety valve, brine |
||
|
-FL11 |
Safety valve, brine |
||
|
-FL12 |
Safety valve, heating medium |
||
|
-FL13 |
Safety valve, heating medium |
||
|
-HQ1 |
Particle filter, brine |
Included in F1345-24/30 |
|
|
-HQ2 |
Particle filter, brine |
Included in F1345-24/30 |
|
|
-HQ3 |
Particle filter, heating medium |
Included in F1345-24/30 |
|
|
-HQ4 |
Particle filter, heating medium |
Included in F1345-24/30 |
|
|
-QM33 |
Shut-off valve, brine in |
Included in F1345-24/30 |
|
|
-QM50 |
Shut off valve, brine |
||
|
-QM51 |
Shut off valve, brine |
||
|
-QM52 |
Shut off valve, brine |
||
|
-QM53 |
Shut off valve, brine |
||
|
-QM54 |
Shut-off valve, heating medium |
||
|
-QM55 |
Shut-off valve, heating medium |
||
|
-QM56 |
Shut-off valve, heating medium |
||
|
-QM57 |
Shut-off valve, heating medium |
||
|
-RM10 |
Non-return valve |
Included in F1345-24/30 |
|
|
-RM11 |
Non-return valve |
Included in F1345-24/30 |
|
|
-RM12 |
Non-return valve |
Included in F1345-24/30 |
|
|
-RM13 |
Non-return valve |
Included in F1345-24/30 |
|
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
6 |
Brine connection, supply |
||
|
7 |
Brine connection, return |
||
|
-CP1.1 |
Storage tank |
||
|
-CP4 |
Additional water heater |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 50 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 50 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-EB1 |
Step-controlled additional heat/electric boiler |
||
|
-RN1 |
Trim valve |
||
|
-QZ1 |
Hot water circulation (HWC) |
||
|
-QZ1-AA25 |
AXC module |
Included in AXC 50 |
|
|
-QZ1-BT70 |
Supply temperature sensor, HWC |
Included in AXC 50 |
|
|
-QZ1-FQ3 |
Mixer valve, HWC |
||
|
-QZ1-GP11 |
Circulation pump, HWC |
||
|
-QZ1-RM1 |
Non-return valve, HWC |
||
|
-QZ1-RN1 |
Trim valve, HWC |
||
|
-RM1 |
Filling connection |
||
|
-QM33 |
Shut off valve, brine flow |
||
|
-XL27 |
Filling brine |
||
|
-XL28 |
Filling brine |
||
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-BP6 |
Pressure gauge, brine |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-CM3 |
Expansion vessel, brine |
||
|
-FL2 |
Safety valve, heating medium |
||
|
-FL3 |
Safety valve, brine |
Included in F1345-24/30 |
|
|
-RM1 |
Non-return valve |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB100 |
Heat pump system |
F1345-40/60 |
|
|
-EP14 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
|
|
-EP15 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
|
|
-EB100-BT6 |
Controlling hot water sensor |
Included in F1345-40/60 |
|
|
-EB100-BT7 |
Display hot water sensor |
Included in F1345-40/60 |
|
|
-EB100-BT25 |
External supply temperature sensor |
Included in F1345-40/60 |
|
|
-EB100-BT71 |
External return line sensor |
Included in F1345-40/60 |
|
|
-EB100-GP10 |
External heating medium pump |
||
|
-EB100-QN10 |
Diverter valve, heating/hot water |
See the valve’s manual for a port description. |
|
|
-BT1 |
Outside sensor |
Included in F1345-40/60 |
|
|
-FL10 |
Safety valve, brine |
||
|
-FL12 |
Safety valve, heating medium |
||
|
-FL13 |
Safety valve, heating medium |
||
|
-HQ1 |
Particle filter, brine |
Included in F1345-40/60 |
|
|
-HQ2 |
Particle filter, brine |
Included in F1345-40/60 |
|
|
-HQ3 |
Particle filter, heating medium |
Included in F1345-40/60 |
|
|
-GP16 |
Circulation pump, brine |
Included in F1345-40/60 |
|
|
-QM33 |
Shut-off valve, brine in |
||
|
-QM50 |
Shut off valve, brine |
||
|
-QM53 |
Shut off valve, brine |
||
|
-QM54 |
Shut-off valve, heating medium |
||
|
-QM55 |
Shut-off valve, heating medium |
||
|
-QM56 |
Shut-off valve, heating medium |
||
|
-QM57 |
Shut-off valve, heating medium |
||
|
-RM10 |
Non-return valve |
Included in F1345-40/60 |
|
|
-RM12 |
Non-return valve |
Included in F1345-40/60 |
|
|
-RM13 |
Non-return valve |
Included in F1345-40/60 |
|
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
6 |
Brine connection, supply |
||
|
7 |
Brine connection, return |
||
|
-CP1.1 |
Storage tank |
||
|
-CP4 |
Additional water heater |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 50 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 50 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-EB1 |
Step-controlled additional heat/electric boiler |
||
|
-RN1 |
Trim valve |
||
|
-QZ1 |
Hot water circulation (HWC) |
||
|
-QZ1-AA25 |
AXC module |
Included in AXC 50 |
|
|
-QZ1-BT70 |
Supply temperature sensor, HWC |
Included in AXC 50 |
|
|
-QZ1-FQ3 |
Mixer valve, HWC |
||
|
-QZ1-GP11 |
Circulation pump, HWC |
||
|
-QZ1-RM1 |
Non-return valve, HWC |
||
|
-QZ1-RN1 |
Trim valve, HWC |
||
|
-RM1 |
Filling connection |
||
|
-QM33 |
Shut off valve, brine flow |
||
|
-XL27 |
Filling brine |
||
|
-XL28 |
Filling brine |
||
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-BP6 |
Pressure gauge, brine |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-CM3 |
Expansion vessel, brine |
||
|
-FL2 |
Safety valve, heating medium |
||
|
-FL3 |
Safety valve, brine |
Included in F1345-40/60 |
|
|
-RM1 |
Non-return valve |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-AA35 |
Control module |
SMO S40 |
|
|
-AA35-BT1 |
Outside sensor |
Included in SMO S40 |
|
|
-AA35-BT6 |
Controlling hot water sensor |
Included in SMO S40 |
|
|
-AA35-BT7 |
Display hot water sensor |
Included in SMO S40 |
|
|
-AA35-BT25 |
External supply temperature sensor |
Included in SMO S40 |
|
|
-AA35-BT71 |
External return line sensor |
Included in SMO S40 |
|
|
-AA35-GP10 |
External heating medium pump |
||
|
-AA35-GP12.1 |
Charge pump for EB101 |
NIBE CPD 11 |
|
|
-AA35-QN10 |
Diverter valve, heating/hot water |
See the valve’s manual for a port description. |
|
|
-EB101 |
Heat pump |
NIBE F2120/F2050/F2040 |
For more information, see the Installer Manual for the heat pump |
|
-EB101-FL10 |
Safety valve, heating medium |
||
|
-EB101-QM1 |
Drain valve, heating medium |
||
|
-EB101-QM40 |
Shut-off valve, heating medium |
||
|
-EB101-QZ2 |
Filterball, heating medium |
||
|
-EB101-RM1 |
Non-return valve, heating medium |
||
|
-RM1 |
XL connections |
||
|
XL1 |
Heating medium connection, supply |
||
|
XL2 |
Heating medium connection, return |
||
|
-CP1.1 |
Storage tank |
||
|
-CP4 |
Additional water heater |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 30 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 30 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-EB1 |
Step-controlled additional heat/electric boiler |
||
|
-RN1 |
Trim valve |
||
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-FL2 |
Safety valve, heating medium |
||
|
-RM1 |
Non-return valve |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB101 |
Heat pump |
NIBE F2120/F2050/F2040 |
For more information, see the Installer Manual for the heat pump. |
|
-EB101-FL10 |
Safety valve, heating medium |
||
|
-EB101-QM1 |
Drain valve, heating medium |
||
|
-EB101-QM40 |
Shut-off valve, heating medium |
||
|
-EB101-QZ2 |
Filterball, heating medium |
||
|
-EB101-RM1 |
Non-return valve, heating medium |
||
|
XL1 |
Heating medium connection, supply |
||
|
XL2 |
Heating medium connection, return |
||
|
-EB15 |
Indoor module |
VVM S320 |
|
|
-EB15-BT1 |
Outside sensor |
Included in VVM S320 |
|
|
-EB15-BT25 |
External supply temperature sensor |
Included in AXC 40 |
|
|
-EB15-GP10 |
Circulation pump, heating medium external |
||
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
3 |
Cold water connection |
||
|
4 |
Hot water connection |
||
|
8 |
Docking connection, supply (from heat pump) |
||
|
9 |
Docking connection, return (to heat pump) |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 40 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 40 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-EM1 |
Miscellaneous |
||
|
-RM1 |
Non-return valve |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB101 |
Heat pump |
NIBE F2120/F2050/F2040 |
For more information, see the Installer Manual for the heat pump. |
|
-EB101-FL10 |
Safety valve, heating medium |
||
|
-EB101-QM1 |
Drain valve, heating medium |
||
|
-EB101-QM40 |
Shut-off valve, heating medium |
||
|
-EB101-QZ2 |
Filterball, heating medium |
||
|
-EB101-RM1 |
Non-return valve, heating medium |
||
|
XL1 |
Heating medium connection, supply |
||
|
XL2 |
Heating medium connection, return |
||
|
-EB15 |
Indoor module |
VVM 310 |
|
|
-EB15-BT1 |
Outside sensor |
Included in VVM 310 |
|
|
-EB15-BT25 |
External supply temperature sensor |
Included in AXC 40 |
|
|
-EB15-GP10 |
Circulation pump, heating medium external |
||
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
3 |
Cold water connection |
||
|
4 |
Hot water connection |
||
|
8 |
Docking connection, supply (from heat pump) |
||
|
9 |
Docking connection, return (to heat pump) |
||
|
18 |
Docking connection, supply (high temp) |
||
|
19 |
Docking connection, return (high temp) |
||
|
30 |
Expansion vessel connection |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 40 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 40 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-FL2 |
Safety valve, heating medium |
||
|
-RM1 |
Non-return valve |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB101 |
Heat pump |
NIBE F2120/F2050/F2040 |
For more information, see the Installer Manual for the heat pump. |
|
-EB101-FL10 |
Safety valve, heating medium |
||
|
-EB101-QM1 |
Drain valve, heating medium |
||
|
-EB101-QM40 |
Shut-off valve, heating medium |
||
|
-EB101-QZ2 |
Filterball, heating medium |
||
|
-EB101-RM1 |
Non-return valve, heating medium |
||
|
XL1 |
Heating medium connection, supply |
||
|
XL2 |
Heating medium connection, return |
||
|
-EB15 |
Indoor module |
VVM 310 |
|
|
-EB15-BT1 |
Outside sensor |
Included in VVM 310 |
|
|
-EB15-BT25 |
External supply temperature sensor |
Included in AXC 40 |
|
|
-EB15-GP10 |
Circulation pump, heating medium external |
||
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
3 |
Cold water connection |
||
|
4 |
Hot water connection |
||
|
8 |
Docking connection, supply |
||
|
9 |
Connecting hot water heater |
||
|
18 |
Docking connection, supply |
||
|
19 |
Connecting hot water heater |
||
|
30 |
Expansion vessel connection |
||
|
-EM1/-EP30 |
Wood/pellet boiler or solar heating system |
||
|
-EM1/-EP30-AA25 |
AXC module |
Included in DEH 310/SCA 35 |
DEH 310 in case of wood/pellet boiler and SCA 35 in case of solar heating system |
|
-EM1/-EP30-GP10 |
Circulation pump |
||
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-FL2 |
Safety valve, heating medium |
||
|
-RM1 |
Non-return valve |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB101 |
Heat pump |
NIBE F2120/F2050/F2040 |
For more information, see the Installer Manual for the heat pump. |
|
-EB101-FL10 |
Safety valve, heating medium |
||
|
-EB101-QM1 |
Drain valve, heating medium |
||
|
-EB101-QM40 |
Shut-off valve, heating medium |
||
|
-EB101-QZ2 |
Filterball, heating medium |
||
|
-EB101-RM1 |
Non-return valve, heating medium |
||
|
XL1 |
Heating medium connection, supply |
||
|
XL2 |
Heating medium connection, return |
||
|
-EB15 |
Indoor module |
VVM 500 |
|
|
-EB15-BT1 |
Outside sensor |
Included in VVM 500 |
|
|
-EB15-BT25 |
External supply temperature sensor |
Included in AXC 40 |
|
|
-EB15-GP10 |
Circulation pump, heating medium external |
||
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
3 |
Cold water connection |
||
|
4 |
Hot water connection |
||
|
8 |
Docking connection, supply (from heat pump) |
||
|
9 |
Docking connection, return (to heat pump) |
||
|
13 |
Solar heat connection, supply |
||
|
14 |
Solar heat connection, return |
||
|
18 |
Docking connection, supply (high temp) |
||
|
19 |
Docking connection, return (high temp) |
||
|
30 |
Expansion vessel connection |
||
|
39 |
Docking connection, pool |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in AXC 40 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 40 |
|
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-FL2 |
Safety valve, heating medium |
||
|
-RM1 |
Non-return valve |
Designations according to standard EN 81346-2.
|
Designation |
Name |
Specification |
Comments |
|---|---|---|---|
|
-EB101 |
Heat pump |
NIBE F2120/F2050/F2040 |
For more information, see the Installer Manual for the heat pump. |
|
-EB101-FL10 |
Safety valve, heating medium |
||
|
-EB101-QM1 |
Drain valve, heating medium |
||
|
-EB101-QM40 |
Shut-off valve, heating medium |
||
|
-EB101-QZ2 |
Filterball, heating medium |
||
|
-EB101-RM1 |
Non-return valve, heating medium |
||
|
XL1 |
Heating medium connection, supply |
||
|
XL2 |
Heating medium connection, return |
||
|
-EB15 |
Indoor module |
VVM 500 |
|
|
-EB15-BT1 |
Outside sensor |
Included in VVM 500 |
|
|
-EB15-BT25 |
External supply temperature sensor |
Included in AXC 40 |
|
|
-EB15-GP10 |
Circulation pump, heating medium external |
||
|
-RM1 |
XL connections |
||
|
1 |
Heating medium connection, supply |
||
|
2 |
Heating medium connection, return |
||
|
3 |
Cold water connection |
||
|
4 |
Hot water connection |
||
|
8 |
Docking connection, supply |
||
|
9 |
Connecting hot water heater |
||
|
13 |
Solar heat connection, supply |
||
|
14 |
Solar heat connection, return |
||
|
18 |
Docking connection, supply |
||
|
19 |
Connecting hot water heater |
||
|
30 |
Expansion vessel connection |
||
|
39 |
Docking connection, pool |
||
|
-EM1 |
Wood/pellet boiler |
||
|
-EM1-AA25 |
AXC module |
Included in DEH 500 |
|
|
-EM1-BT52 |
Boiler sensor |
Included in AXC 40 |
|
|
-EM1-GP10 |
Circulation pump |
||
|
-EM1-CM1 |
Expansion vessel, heating medium |
||
|
-EM1-FQ1 |
Thermal mixing valve |
||
|
-EM1-QN11 |
Shunt valve for additional heat |
||
|
-EM1-FN2 |
Charge pump, external heat source |
||
|
-EM1-FL2 |
Safety valve, heating medium |
||
|
-EM1-CP1 |
Storage tank |
||
|
-RM1 |
Miscellaneous |
||
|
-BP5 |
Pressure gauge, heating medium |
||
|
-CM1 |
Closed expansion vessel, heating medium |
||
|
-FL2 |
Safety valve, heating medium |
||
|
-RM1 |
Non-return valve |
Designations according to standard EN 81346-2.